• In iFix5.8 if we make systemmenu to False from property window, left side logo also going off.(on title bar iFix logo)
    But in iFix 5.5,if we make systemmenu to False only 3 buttons are going off,the logo remains on title bar.
    Is there any way to remove/disable that logo in a aprticular window?
    Tue May 03 16:00:17 GMT 2016 Answer Like 0 Follow 0
  • Cimplicity Version 9.0 SIM 13
    With this new version, when I restart the project on the server, every workstation pops up a message with the above warning.
    Each workstation has to manually clear the message.This didn't happen previously.
    Is there any way to prevent the dialog message from appearing?

    Thanks!
     
    Tue May 03 12:29:55 GMT 2016 Answer Like 0 Follow 0
  • I want to be able to see the implicity references inside of a SHIFTR_WORD in PME 7.0 logic developer I have tried using datawatch but when I enter the reference address that are not defined (starting address for the register) I only get ??? in the data watch value column.  Does anyone know how to actively monitor the values?
    Mon May 02 22:48:15 GMT 2016 Like 0 Follow 0
    Best Answer chosen by bill2bhappy
    Assign the variable associated with the starting address a dimension equal to the length of the SHIFTR_WORD instruction instead of the default dimension of 1. Then all elements of the array will show up in the data watch window.
    Or, you can create a custom reference view table to show all the addresses you need.
    Tue May 03 01:19:21 GMT 2016 1 0
    Show 2 Answers
  • I have a GE Fanuc 90-30 series PLC in a Spectra Panelboard.
    Our panelboard was instaled on 1998; the PLC batery and UPS backup fail at same time and we loss the program. Now the emergency generator didn´t work in automatic function.

    How can I do to recover the PLC program to reinstal it?
    Mon May 02 20:09:03 GMT 2016 Like 0 Follow 0
    Show 1 Answer
  • Russ

    How to use the Community Video...

    posted in Knowledge Center
    This how to use the Community Video should be a link at the top of each Community Page.
    https://ge-ip.force.com/communities/en_US/Video/Customer-Center-Knowledge
     
    Mon May 02 13:32:16 GMT 2016 Answer Like 0 Follow 0
  • JWait1452269944

    I/O faultTable

    posted in VersaMax Micro & Nano
    I have written software for my company that allows for different configurations of our final product with various amounts of added features. The higher end units call for additional expansion units attached to a Micro 23 PLC.  When I download the software and on each power up, an error is logged into the I/O Fault Table "%AI00024 loss of exp unit".  The software runs just fine which is the intent but I am wondering will this fault create a problem ( unit failure ) after a long period ?  That is, will it be necessary to connect to the unit and through Proficy clear the fault table ? Or will this type of fault just be ignored and never creat a problem.
    Is there a way to clear the fault tables with a command in the ladder logic ?
    Mon May 02 11:53:55 GMT 2016 Like 0 Follow 0
    Show 2 Answers